| PvcClientVpi |
Vpi. |
| PvcClientVci |
Vci. |
| FlowLevel |
The OAM hierarchical flow levels : VC (F5) or VP (F4). Enumerations: |
| LoopbackEnd2End |
Indicates if OAM loopback is enabled from end to end connection. Enumerations: |
| LoopbackSegment |
Indicates if OAM loopback is enabled onto the segment connection. Enumerations: |
| LoopbackTxTimer |
OAM loopback transmit timer (in seconds). Default value = 5 |
| LoopbackTxCount |
Specifies the number of OAM loopback cells to send to the target
in this sequence. |
| LoopbackEnd2EndTxCells |
The number of OAM loopback cells (for end to end) that have been sent
to the target in this sequence. |
| LoopbackEnd2EndRxCells |
The number of OAM loopback cells (for end to end) that have been received
from the target in this sequence. |
| LoopbackSegmentTxCells |
The number of OAM loopback cells (for segment) that have been sent
to the target in this sequence. |
| LoopbackSegmentRxCells |
The number of OAM loopback cells (for segment) that have been received
from the target in this sequence. |
| CCEnd2End |
Indicates if OAM continuity check activation request is
activated from end to end connection. Enumerations: |
| CCSegment |
Indicates if OAM continuity check activation request is
activated onto the segment connection. Enumerations: |
| CCActivationResp |
The OAM continuity check activation response.
Could be confirm(1) or deny(2). Enumerations: |
| CCEnd2EndTxCells |
The number of OAM continuity check cells (for end to end)
that have been sent to the target in this sequence. |
| CCEnd2EndRxCells |
The number of OAM continuity check cells (for end to end)
that have been received from the target in this sequence. |
| CCSegmentTxCells |
The number of OAM continuity check cells (for segment)
that have been sent to the target in this sequence. |
| CCSegmentRxCells |
The number of OAM continuity check cells (for segment)
that have been received from the target in this sequence. |
| AisEnd2EndTxCells |
The number of OAM alarm indication signal (AIS) cells
(for end to end) that have been transmitted to the target
in this sequence. |
| AisEnd2EndRxCells |
The number of OAM alarm indication signal (AIS) cells
(for end to end) that have been received from the target
in this sequence. |
| AisSegmentTxCells |
The number of OAM alarm indication signal (AIS) cells
(for segment) that have been transmitted to the target
in this sequence. |
| AisSegmentRxCells |
The number of OAM alarm indication signal (AIS) cells
(for segment) that have been received from the target
in this sequence. |
| RdiEnd2EndTxCells |
The number of OAM remote defect indication (RDI) cells
(for end to end) that have been transmitted to the target
in this sequence. |
| RdiEnd2EndRxCells |
The number of OAM remote defect indication (RDI) cells
(for end to end) that have been received from the target
in this sequence. |
| RdiSegmentTxCells |
The number of OAM remote defect indication (RDI) cells
(for segment) that have been transmitted to the target
in this sequence. |
| RdiSegmentRxCells |
The number of OAM remote defect indication (RDI) cells
(for segment) that have been received from the target
in this sequence. |
| CCEnd2EndDirection |
Indicates OAM continuity check direction (for end to end).
Possible directions are : B-A (1), A-B (2) and two-way (3). Enumerations: |
| CCSegmentDirection |
Indicates OAM continuity check direction (for segment).